Usage and attention of anti-glare flood light

Anti-glare floodlights are widely used in various indoor main plant, pump room, boiler room, gallery, trestle, furnace body, coal warehouse and other places for fixed lighting.

Instructions

1. Determine the installation location of the lamp, select the appropriate installation method, and press the lamp to the distance of the 220V power contact point, and prepare the corresponding length of the φ6~8mm three-core cable;

2. Open the back cover by pulling the two locks on the lamp holder. Pass one end of the prepared three-core cable through the inlet, and connect the live wire (L) to the “L” terminal. The neutral wire (N) is connected to the cover. On the “N” terminal, the ground wire (PE) is connected to the “PE” terminal. After the cable of the inlet is pressed with the compression nut, the back cover is closed, the latch is fastened, and finally the three-core cable is connected. The other end is turned on to achieve lighting.

3. When replacing the bulb, open the rear cover according to the method of use. 2. Turn the lamp holder clockwise and gently pull it out of the lamp cover. Unscrew the old lamp on the lamp holder and replace it with a new one.

4, installation:

Ceiling Mounting: First use four M8 bolts to fix the lifting adapter plate to the lamp. Connect the three-core cable through the G3/4 pipe thread opening, through the round hole on the side and the introduction port on the lamp holder side. On the luminaire, the G3/4 pipe thread of the luminaire is then screwed together with the wiring pipe with standard G3/4 pipe thread.

Ceiling installation: According to the installation hole size of the lamp, the corresponding bolt hole is to be installed at the position where the lamp is to be installed and fixed with the M8 bolt.

5, multiple lights in parallel.

Precautions

1. When the light is transported, it should be installed in the equipped carton and be equipped with foam shock absorption.

2. When used, there is a certain temperature rise on the surface of the lamp, which is a normal phenomenon; the center temperature of the transparent part is relatively high and must not be touched.

3, when replacing the bulb, should use the same type, power bulb; if you change the bulb type or power, should replace the matching ballast.

Agrochemical Intermediates

Agrochemical Intermediates,CAS 7446-70-0,Vitamin H,Hight Purity Dimethyldichlorosilane

Quzhou CanWin New Material Co., Ltd. , https://www.canwinnm.com