Security monitor three faults and solutions

[ Huaqiang Security Network News ] Monitors in security monitoring are very important. Because in the monitoring system, if there is a phase difference in the field sync signal in the image signal outputted by each front-end device (such as a camera), when the matrix controller switches each image signal, the monitor will appear out of sync for a period of time. Phenomenon, the greater the phase difference, the longer the time to synchronize. Therefore, it is recommended to use a front-end device with external synchronization (GEN-LOOK) input when constructing the monitoring system, and all front-end devices use the external synchronization mode, that is, the synchronization of each image signal is controlled by the same synchronization signal. Causes the monitor screen to display synchronization.
When using a monitor to observe an image, why do image distortions, distortions, unsynchronized fields, or even input signals fail?
Security monitor
1. The industry standard for monitors specifies that the input signal amplitude of a professional monitor is 1Vp-P±3dB (about 0.7Vp-P-1.4Vp-p) and the input impedance is 75 ohms. Therefore, if the input signal is not standardized due to cable attenuation, impedance mismatch or BNC head of the transmission cable, the input signal amplitude is much lower than 0.7pp; or because the output of the camera is not standardized or some irregularities are accessed. When the access device (such as a distributor, amplifier, etc.) causes the input signal amplitude to be much larger than 1.4Vp-p, the image distortion and the line field may be unsynchronized.
2. Due to the wide frequency range of video, video signals are more susceptible to interference during transmission (including 50Hz power supply interference, electromagnetic wave interference, etc.), thus affecting image quality. Serious interference may result in image distortion, distortion, raceway, and field synchronization. Therefore, during the installation of the monitoring system, the video line must be kept away from electromagnetic interference sources.
3. The potential difference between the front-end device, the control host device and the terminal device may also interfere with the video signal, causing distortion of the image signal or image rolling, if the entire system is powered on (ie front-end equipment, master control) When the device and the terminal device are both connected to the front and rear devices of the BNC head when they are powered on, the ground potential may be caused by the potential difference between the ground wire of the front and rear devices (actually the shielding layer of the transmission cable). Fire, this severe fire will destroy the components at the input or the ground level wire in the PCB casserole. The input is open and the input has no image failure. Therefore, the construction of the monitoring system project should be designed and constructed in strict accordance with the specifications. The grounding busbar shall be made of copper conductor with sufficient cross-sectional area to ensure that the ground-to-ground resistance of the front and rear ends is <1Ω. The grounding wire shall not form a closed loop and shall not be short-circuited or mixed with the neutral line of the strong power grid.

We believe a new enclosure is something to look forward to. That`s why we want to save you time and energy when it comes to buying yours. It doesn`t matter how small your bathroom is, or if you`re opting for something different like a wet room, you`ll find exactly what you`re looking for in our extensive range of Shower Enclosures. Get inspired with contrasting frames and finishes, and panels perfect for His-and-Hers showers. And don`t forget to view our shower trays, which come in a range of quality materials for a luxury feel underfoot.Shower Enclosures


Shower Enclosures

Shower Enclosures Quadrant,Shower Enclosures,Diamond Shower Enclosure,Shower Glass Doors

Pinghu Relax Sanitary Ware CO.,ltd , https://www.relaxsanitary.com