During the renovation of the house, I realized that many electrical appliances couldn’t be installed properly due to insufficient power supply or lack of pre-planned wiring and space. To avoid such issues, it’s crucial to plan ahead by embedding the necessary pipelines during the decoration phase.
It's important to have separate wiring for the microwave and refrigerator. These appliances require a dedicated circuit due to their high power consumption. Make sure to reserve separate lines before the renovation and keep the wiring away from heat sources like the stove to prevent any safety hazards.
Before painting the walls, decide on the air conditioner model and let the technician drill the hole and install the indoor unit bracket. This ensures a clean finish without damaging the decor. The outlet should also be placed close to the air conditioner and used exclusively for it. Most standard units require a 10-amp socket, but high-power models may need a professional-grade outlet.
Before laying the floor, make sure to install all audio and video cables. Whether you're planning to add sound or not, it's best to run the wires first. If you forget this step, you'll end up with messy cables on the floor later, which can ruin the look of your home.
If the developer hasn’t already set up the drainage for the washing machine, you’ll need to pre-position the hole during renovation. Also, ensure the power socket is installed in a dry area. If the washing machine is in the bathroom, the socket should be at least 1.2 meters above the ground, and its location should be determined early in the process.
When installing a bath heater (Yuba), consider ventilation and ducting beforehand. It shouldn’t be too close to the ceiling—ideally between 15cm and 20cm. Keep the power supply away from moisture to avoid electrical risks, and make sure it’s not too low to the ground.
For solar water heaters, the plumbing and wiring must be prepared in advance. A three-core cable with proper grounding is essential for safety. Place the control unit in a suitable location, like the toilet, and ensure the water solenoid valve and roof control circuits are properly connected. Top-floor users may benefit from an additional booster pump for better water pressure.
Instant electric water heaters require careful consideration of your home’s electrical system. These units typically need at least 6 kW of power, ideally 8 kW. During renovation, a dedicated line with a 4–6 mm² cable should be installed. Some high-end models allow for hidden piping, so pre-embedding the pipes and wires according to the manufacturer’s specifications will result in a cleaner, more aesthetic installation.
When installing a water purifier, make sure both water and power connections are ready at the installation spot. If you want to have filtered water in the living room, connect the water pipe there during renovation.
Flat-screen TVs are lightweight and easy to mount, but they generate significant heat. Ensure enough ventilation space is left around the TV to prevent overheating and damage. It’s also recommended to have multiple outlets behind the TV wall for convenience.
For kitchen appliances like range hoods, microwaves, and refrigerators, plan the power switches and sockets in advance. Measure the size of any built-in appliances and reserve space accordingly. The range hood should be positioned correctly to avoid installation issues. Additionally, think about where other appliances will go and address any water-related concerns, especially with dishwashers.
Automatic Control Mechanical Diaphragm Dosing Pump
Automatic Control Mechanical Diaphragm Dosing Pump(impulse control metering pump)
*Chemical used: sodium hypochlorite, aluminum sulfate, ferric chloride, PAC, sulfuicacid, phoshoric acid, urea, anti foams, calcium chloride, aluminium chloride
*Stainless ball suggested to use chemical like: coagulant, ammonia water, hydrazine, caustic soda
*Pump can be used in water circulation cooling, purification of water, sewage treatment, laboratory and testing room, other small size measuring equipment
*Easily installation, simple operation and convenience maintenance, ready to use for customer
*High measurement precisions, capacity can be adjusted from 0 to 100 percent during operation
*Strong anti-corrosiveness, used for quite range of chemical
*Economical and practical
*Durable diaphragm: mechanical actuated diaphragm, leakage free
* Rugged construction designed which allowed pump to provide safe services at severe operation condition
*Changeable eccentric drive, no leakage with security delivery
*The pump can be used to deliver the solution which is high-viscosity, corrosive and dangerous
*Diaphragm rupture detection system, double diaphragm, is optional
Ce Certification Mechanical Diaphragm Chemical Dosing Pump,Large Automatic Control Mechanical Diaphragm Dosing Pump,Mechanical Diaphragm Duplex Cylinder Diaphragm Dosing Pump,Impulse Control Metering Pump
Zhejiang Ailipu Technology Co., Ltd. , https://www.alipu.com