Multi-stage pump failure and solution

Multi-stage pump in the process of using this or that failure may occur, Xiaobian to sort out the multi-stage pump common faults and solutions, we can collect it for emergency use. Multi-stage pump failure a: The pump is not suction pressure gauge and the vacuum gauge pointer violently beating Reason: 1. Insufficient filling perfusion 2. Pipeline and instrumentation joints leak 3. Suction too high Solution: 1. Check the end valve is leaking Re-hire enough water 2. Tighten the leak 3. Lower the height of the water Fault II: The pump does not absorb water Vacuum indicates a high degree of vacuum Cause: 1. The end of the valve is not open or blocked 2. The suction pipe is too heavy 3. The filter Blockage solution: 1. Check the end of the valve 2. Replace the suction 3. Clean the filter failure Three: the pressure gauge but there is still no water pressure reasons: 1. The outlet pipe resistance is too large 2. Rotation direction wrong 3. The outlet pipe valve is not Open 4. Impeller clogging solution: 1. Check or ç¼— short hose 2. Check the motor. Two intermodulation 3. Open the outlet valve 4. Remove the dirt inside the impeller Fault 4. Reach the design flow reasons: There is air inhalation 2. As the water level decreases. Insufficient depth of submergence 3. There are foreign body impeller plug 4. Rotor part of the serious wear and tear Solution: 1. Check the leaking parts and exclude 2. Extend the suction pipe. Deepen the depth of flooding 3. Demolition and Dripping foreign body 4. Replace the seal ring failure Five: pump power consumption is too large Reason: 1. Fill Pressure too tight. And fever 2. Flow too large 3. Swivel and shell have friction 4. Pump bearing wear 5. Pump shaft bending solution: 1. Appropriate relaxation packing pressure 2. Off gate valve opening 3 . Trim slewing body and housing location 4. Replace the bearing 5. Replace or correct the problem VI: Pump vibration increase Cause: 1. Impeller partial plugging 2. Impeller damage 3. Flow is too small 4. Pump shaft and the motor is not the heart 5 . Bearing damage 6. Mixed with air. Cavitation occurs Solution: 1. Removal and removal of foreign matter 2. Replace the impeller 3. Open the outlet valve 4. Fixed point fix 5. Change the suction bit. Improve the water absorption. Exhibition water Expo Xiamen exhibition of marine equipment Internet + Forum Yiwu Fair 2016 exhibition mold top ten brands of the Internet information industry (Xiamen) Technology Co., Ltd. author: Asian pumps network editor: Yao Xiaoxia (QQ / micro letter:) http: / /beng.liuti.cn/ (Service Hotline:)

  • Material Brass
    Color Chrome

    Suitable place

    Bathroom ,toilet
    Suitable use for Pet baths,PP wash ,douche,baby diapers
    Install connect size

    G1/2"

    Hose Stainless steel 1.5m
    Warranty time 2 Years.
    FOB Port Guangzhou,Shenzhen
    Sample lead time: 1-3 Working Days
    Payment T/T,Money Gram,Paypal
    Packaging Detail box.it can be designed as your need



  • High Quality Parts - We use high quality parts that are built to last making Luxe Bidet an excellent value for the price. Solid inner construction with high-pressure valves, strong brass t-adapter, hose, and sprayer holster, and a chrome-plated sprayer head.

Brass Handheld Bidet Shattaf

Brass Handheld Bidet Shattaf,Brash Shattaf,Handheld Bidet Shattaf,Brass Shower Sprayer for Toilet

Yuyao Sanyin Bathroom Technology Co Ltd , https://www.chinasanyin.com